For Acuity Laser AR1000 Laser Distance Sensor Replacement | 150 m Measuring Range with a Retroreflective TargetFor Acuity Laser AR1000 Laser Distance Sensor Replacement | 150 m Measuring Range with a Retroreflective TargetFor Acuity Laser AR1000 Laser Distance Sensor Replacement | 150 m Measuring Range with a Retroreflective TargetFor Acuity Laser AR1000 Laser Distance Sensor Replacement | 150 m Measuring Range with a Retroreflective TargetFor Acuity Laser AR1000 Laser Distance Sensor Replacement | 150 m Measuring Range with a Retroreflective Target
CategoriesAcuity Laser Long Range Sensors Replacement
BrandDADISICK
ModelAR1000 Series | AR1000
Series:AR1000 Series
Measuring range:0.1 to 150 m
Light spot size:5.1 mm, 0.6 mrad divergence
Measurement accuracy:± 3 mm
Resolution:1 mm
Update TimeJan 10,2025
Detail Information
For Acuity Laser AR1000 Laser Distance Sensor Replacement | 150 m Measuring Range with a Retroreflective Target
Brand
From network
DADISICK
Models
AR1000
DS-200
Measuring range
0.1 to 150 m Measuring Range with a Retroreflective Target
MAX. 200 m
Light spot size
5.1 mm, 0.6 mrad divergence
245 mm (@200 m)
Measurement accuracy
± 3 mm
±2 mm
Repeatability
≥ 0.5 mm
1 mm
Measurement frequency
50 Hz maximum, or sample trigger (serial command and analog)
1000 Hz
Resolution
1 mm
0.1 mm
Max. movement speed
15 m/s
Supply voltage
10 - 30 Volts DC, 50 – 150 mA draw . (AR1000H 24W at 24VDC with heater)
DC 9 V ... 30 V
Current consumption
0.2 A at 12 V DC
Laser class
Class 2, Complies with 21 CFR 1040.10 with Laser Notice 50, IEC/EN60825-1:2001
Class 2
Light source
650 nm, 1 mW visible RED
Red laser (visible light)
Interface
Serial: RS232 full duplex, RS422 (optional) unterminated and terminated;
Analog: 4-20 mA, limit switch
SSI, Ethernet 100BASE-TX (Data Transmission)
Connection
(2 m) length, 12 conductor, Binder series 723 flange-mount connector, 
soldertail wire termination
M12/4-pin/D-coded female straight (For Network);
M12/8-pin/A-coded male straight (For Power/SSI)
Dimensions
123 × 69.5 × 90 mm
IP rating
IP65
IP65
Operating temperature
-10 to 50 °C
-10℃~+55℃
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product Model Display Instructions
The brands and specifications displayed on this page are for reference and product selection purposes only. The Laser Distance Sensors we provide are manufactured by DADISICK and are not official products of Acuity Laser or any other brand mentioned. DADISICK offers compatible alternatives to official brand products. We do not own the rights to these brands. For genuine Acuity Laser products, please contact the brand's authorized representative directly.
Product Recommendations
DS Series Long-Distance Laser Rangefinder
DS Series Long-Distance Laser Rangefinder
Model:
DS-80
DS-120
DS-200

FAQ
1. How suitable is the DS Series for harsh environments?
The DS Series features an IP65 protection rating, making it suitable for dusty and humid industrial environments. However, it is not designed for use in corrosive or explosive conditions.

2. Can the device be modified?
No, any electrical or mechanical modification is prohibited. Unauthorized software should also not be used with the device.

3. What qualifications should operators possess?
- Mechanical installation personnel should have knowledge of mechanical technology and safety.
- Electrical installation personnel should have expertise in electrical technology, safety, and equipment operation experience.
- Commissioning personnel should be familiar with operating systems, data transmission, and interface configuration basics.

4. Is laser radiation harmful to humans?
Short-term exposure (≤0.25 seconds) is not harmful, but prolonged direct exposure may cause retinal damage. Operators should wear protective eyewear and avoid laser reflections.

5. What precautions should be taken for electrical operation?
- Operations must be carried out by professional electrical personnel. o Electrical connections should be made while the power is off.
- The product must be connected to a power source that meets the requirements specified in the user manual.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Dimensions
DS Series Long-Distance Laser Rangefinder Dimensions
Connection Description
 Network Interface: M12/4-pin/D-coded female straight
 Network Interface: M12/4-pin/D-coded female straight
Power/SSI Interface: M12/8-pin/A-coded male straight
Power/SSI Interface: M12/8-pin/A-coded male straight
DS Series Long Distance Sensor Software User Manual
DS Series Communication Protocol_V1.0.1
Laser Rangefinder DS Series User Manual

Laser Rangefinder DS Series Data Sheet
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions