For PILZ PNOZ X Series Replacement 24 V AC/DC, 48 - 240 V AC/DC Supply Voltage 2 N/O Output PNOZ X2.1 PNOZ X2P PNOZ X7 Safety Relay

For PILZ PNOZ X Series Replacement 24 V AC/DC, 48 - 240 V AC/DC Supply Voltage 2 N/O Output PNOZ X2.1 PNOZ X2P PNOZ X7 Safety Relay

For PILZ PNOZ X Series Replacement 24 V AC/DC, 48 - 240 V AC/DC Supply Voltage 2 N/O Output PNOZ X2.1 PNOZ X2P PNOZ X7 Safety Relay
For PILZ PNOZ X Series Replacement 24 V AC/DC, 48 - 240 V AC/DC Supply Voltage 2 N/O Output PNOZ X2.1 PNOZ X2P PNOZ X7 Safety RelayFor PILZ PNOZ X Series Replacement 24 V AC/DC, 48 - 240 V AC/DC Supply Voltage 2 N/O Output PNOZ X2.1 PNOZ X2P PNOZ X7 Safety RelayFor PILZ PNOZ X Series Replacement 24 V AC/DC, 48 - 240 V AC/DC Supply Voltage 2 N/O Output PNOZ X2.1 PNOZ X2P PNOZ X7 Safety RelayFor PILZ PNOZ X Series Replacement 24 V AC/DC, 48 - 240 V AC/DC Supply Voltage 2 N/O Output PNOZ X2.1 PNOZ X2P PNOZ X7 Safety RelayFor PILZ PNOZ X Series Replacement 24 V AC/DC, 48 - 240 V AC/DC Supply Voltage 2 N/O Output PNOZ X2.1 PNOZ X2P PNOZ X7 Safety Relay
CategoriesPilz Safety Relay Replacement
BrandDADISICK
ModelPNOZ X Series | PNOZ X2.1 24VAC/DC 2n/o, PNOZ X2P C 48-240VACDC 2n/o, PNOZ X2P 48-240VACDC 2n/o, PNOZ X2P C 24VACDC 2n/o, PNOZ X2P 24VACDC 2n/o, PNOZ X7 24VACDC 2n/o
Supply voltage24 V AC/DC, 48 - 240 V AC/DC
Power consumptionDC: 1W,1.5W,2W; AC: 3VA,3.5VA,4.5VA
Outputs2 N/O
Rated insulation voltage250 V
Operating temperature-10 - 55 °C
Housing materialABS UL 94 V0, PPO UL 94 V1
Connection terminalScrew terminals, plug-in spring-loaded/screw
Update TimeDec 5,2024
Detail Information
For PILZ PNOZ X Series Replacement Safety Relay Parameter
Brand
From network
DADISICK
Models
PNOZ X2.1 24VAC/DC 2n/o
LS-A
PNOZ X2P C 48-240VACDC 2n/o
PNOZ X2P 48-240VACDC 2n/o
PNOZ X2P C 24VACDC 2n/o
PNOZ X2P 24VACDC 2n/o
PNOZ X7 24VACDC 2n/o
Supply voltage
24 V AC/DC, 48 - 240 V AC/DC
24V DC
Power consumption
DC: 1W,1.5W,2W; AC: 3VA,3.5VA,4.5VA
2.9W
Relay contact material
AgSnO2 + 0.2 µm Au
AgSnO2 + 0.2µmAu
Operating temperature
-10 - 55 °C
-25℃~85℃
Output
2 N/O
3NO+1NC
Connection terminal
Screw terminals integrated
Plug-in screw terminals
Plug-in spring-loaded terminals
Screw terminal
Relay contact capacity
AC1
240 V, 6 A
AC-1
6A/250VAC/1500VA
DC1
24 V, 6 A
AC-15
4A/240VAC
AC15
230 V, 3 A
DC-1
6A/24VDC /150W
DC13
24 V
AC-15
4A/240VAC
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety relay is a safety part made by DADISICK, not an official brand of PILZ's products. DAIDSICK offers replacements for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand's official representative.
Safety Relay Recommendations
DADISICK Safety Relay LS-A
Maximum compliance with ISO13849-1 PLe standard and IEC 62061 SiL3 standard. Proven two-channel security monitoring circuit design. Width 22.5mm to reduce installation space. Screw or spring terminals are available for a wider range of applications. PLC signal output. I/O LED indication.

LS-A series safety relay
Models:
LS-A

Safety Relay FAQ
Q: If a safety relay disconnects the circuit during use, is it a device failure or a dangerous factor detected?
A: Circuit breakage can be caused by many factors. First, check whether there are any dangerous factors, such as potential circuit accidents. If it is confirmed that there are no hidden dangers, the safety relay may be faulty. At this point, you can try restarting the relay. If the problem persists, you need to troubleshoot or replace the relay.
Q: What should I do if the safety relay output contact fuse?
A: The output contact fuse of safety relay, it is usually caused by a short circuit fault or overcurrent. At this time, the new fuse should be replaced and the circuit should be checked for short circuit or overcurrent problems to avoid similar faults from happening again.
Q: What is the difference between automatic reset and manual reset?
A: Automatic reset means there is no reset switch in the feedback circuit and the device starts automatically when the input is turned on. Manual reset means there is a reset switch in the feedback circuit, and when the input is open, the device will not start unless the reset switch is pressed. Manual reset is basically safer and it must be performed after all hazards have been cleared. Therefore, manual reset is used for machines and emergency stop circuits that personnel can enter, and automatic reset is used for machines that personnel cannot enter.
Q: What is the reason why the safety relay contacts cannot separate?
A: Failure separation of the safety relay contacts can be caused by mechanical bonding, welding, or cold welding. In addition, low contact capacity, heavy load, or changes in load characteristics can also cause failure to connect or disconnect the circuit. At this time, check the contact status and replace or adjust if necessary.
Q: How to adjust the operating parameters of the safety relay?
A: When adjusting the operating parameters of a safety relay, its technical parameters, such as contact thickness, open gap, overtravel and terminal pressure, should be measured first to ensure that all parameters meet the requirements of relevant regulations and working documents. Then, adjust the set value of the action parameter according to actual requirements and fix it with stop paint.
Q: What precautions should be taken when using safety relays in combination with other components?
A: When using safety relays in combination with other components, ensure compatibility and coordination between the components. At the same time, relevant safety regulations and operating procedures should be followed to ensure the safety and stability of the entire circuit system.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Relay Dimensions  (Unit: mm)
Safety Relay LS-A Series Dimensions
Safety Relay LS-A Output Wiring Diagram
Safety Relay LS-A Dimensions
Safety Relay LS-A Datasheet
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions