Home / All / ReeR Replacement / ReeR Measuring Light Curtains Replacement /

For ReeR Micron Series 25 mm Beam Spacing 18 m Operating Range 125 mm to 2975 mm Protective Height AV Measurement Light Curtains Replacement

For ReeR Micron Series 25 mm Beam Spacing 18 m Operating Range 125 mm to 2975 mm Protective Height AV Measurement Light Curtains Replacement

For ReeR Micron Series 25 mm Beam Spacing 18 m Operating Range 125 mm to 2975 mm Protective Height AV Measurement Light Curtains Replacement
For ReeR Micron Series 25 mm Beam Spacing 18 m Operating Range 125 mm to 2975 mm Protective Height AV Measurement Light Curtains ReplacementFor ReeR Micron Series 25 mm Beam Spacing 18 m Operating Range 125 mm to 2975 mm Protective Height AV Measurement Light Curtains ReplacementFor ReeR Micron Series 25 mm Beam Spacing 18 m Operating Range 125 mm to 2975 mm Protective Height AV Measurement Light Curtains ReplacementFor ReeR Micron Series 25 mm Beam Spacing 18 m Operating Range 125 mm to 2975 mm Protective Height AV Measurement Light Curtains ReplacementFor ReeR Micron Series 25 mm Beam Spacing 18 m Operating Range 125 mm to 2975 mm Protective Height AV Measurement Light Curtains Replacement
CategoriesReeR Measuring Light Curtains Replacement
BrandDADISICK
ModelMicron Series | MICRON MI 152 AV, MICRON MI 302 AV, MICRON MI 452 AV, MICRON MI 602 AV, MICRON MI 752 AV, MICRON MI 902 AV, MICRON MI 1052 AV, MICRON MI 1202 AV, MICRON MI 1352 AV, MICRON MI 1502 AV, MICRON MI 1652 AV, MICRON MI 1802 AV, MICRON MI 1952 AV, MICRON MI 2102 AV, MICRON MI 2252 AV, MICRON MI 2402 AV, MICRON MI 2552 AV, MICRON MI 2702 AV, MICRON MI 2852 AV, MICRON MI 3002 AV
Series:Micron Series
Beam Spacing:25 mm
Number of beams:6-120
Operating range:18 m
Protective height:125 mm - 2975 mm
Output type:2PNP&0-10VDC
Connection type:M12
IP Degree of protectionIP65, IP67
Update TimeDec 5,2024
Detail Information
For ReeR Micron Series 25 mm Beam Spacing 18 m Operating Range 125 mm to 2975 mm Protective Height AV Measurement Light Curtains Replacement Parameter
Brand
From network
DADISICK
Models
MICRON MI 152 AV
QLT06-20-100
MICRON MI 302 AV
QLT14-20-260
MICRON MI 452 AV
QLT22-20-420
MICRON MI 602 AV
QLT30-20-580
MICRON MI 752 AV
QLT36-20-700
MICRON MI 902 AV
QLT44-20-860
MICRON MI 1052 AV
QLT52-20-1020
MICRON MI 1202 AV
QLT60-20-1180
MICRON MI 1352 AV
QLT66-20-1300
MICRON MI 1502 AV
QLT74-20-1460
MICRON MI 1652 AV
QLT82-20-1620
MICRON MI 1802 AV
QLT88-20-1740
MICRON MI 1952 AV
QLT96-20-1900
MICRON MI 2102 AV
QLT104-20-2060
MICRON MI 2252 AV
QLT112-20-2220
MICRON MI 2402 AV
QLT118-20-2340
MICRON MI 2552 AV
QLT126-20-2500
MICRON MI 2702 AV
QLT134-20-2660
MICRON MI 2852 AV
QLT142-20-2820
MICRON MI 3002 AV
QLT148-20-2940
Beam spacing
25 mm
20 mm
Number of beams
6, 12, 18,24, 30, 36, 42, 48, 54, 60, 66, 72, 78, 84, 90, 96, 102, 108, 114, 120
6, 14, 22, 30, 36, 44, 52, 60, 66, 74, 82, 88, 96, 104, 112, 118, 126, 134, 142, 148
Protective height
125 mm, 275 mm, 425 mm, 575 mm, 725 mm, 875 mm, 1025 mm, 1175 mm, 1325 mm, 1475 mm, 1625 mm, 1775 mm, 1925 mm, 2075 mm, 2225 mm, 2375 mm, 2525 mm, 2675 mm, 2825 mm, 2975 mm
100 mm, 260 mm,420 mm, 580 mm, 700 mm, 860 mm, 1020 mm, 1180 mm, 1300 mm, 1460 mm, 1620 mm, 1740 mm, 1900 mm, 2060 mm, 2220 mm, 2340 mm, 2500 mm, 2660 mm, 2820 mm, 2940 mm
Operating range
18 m
0.3 m - 30 m
Output method
2PNP&0-10VDC
RS485&RS232
PNP
 analog voltage 1-10V
analog current 4-20mA
IP Degree of protection
IP65, IP67
IP65
Connector
M12
M16
Housing cross-section
30 mm × 28 mm
51 mm × 35 mm
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand ReeR's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Measuring Light Curtains
QLT series measuring light curtains

Model:
QLT06-20-100, QLT14-20-260, QLT22-20-420, QLT30-20-580
QLT36-20-700, QLT44-20-860, QLT52-20-1020, QLT60-20-1180
QLT66-20-1300, QLT74-20-1460, QLT82-20-1620, QLT88-20-1740
QLT96-20-1900, QLT104-20-2060, QLT112-20-2220, QLT118-20-2340
QLT126-20-2500, QLT134-20-2660, QLT142-20-2820, QLT148-20-2940


FAQ
Q: Are your measurement light curtains compliant with industry standards ?
A: Yes, our measurement light curtains comply with all relevant industry standards and regulations, ensuring adherence to safety requirements and quality standards. We prioritize safety and reliability in our product design, manufacturing processes, and testing procedures to provide customers with confidence in the performance and compliance of our sensors.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Measuring Light Curtain Wiring Diagrams/Dimensional Drawings
Measuring Light Curtain Cable description
DADISICK Measuring Light Curtain Cable Description
RS485/RS232 Wiring Diagram
DADISICK Measuring Light Curtain RS485/RS232 Wiring Diagram
5-pin analog U/I wiring diagram
DADISICK Measuring Light Curtain 5-pin Anlog U/I Wiring Diagram
Measuring Light Curtain
 Dimension
DADISICK Measuring Light Curtain Dimension
Measuring Light Curtain QLT Series Data Sheet
Measuring Light Curtain QLT Series User Manual
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions