Home / All / ReeR Replacement / ReeR Safety Light Curtains Replacement /

For ReeR EOS2 Series 40 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height X Safety Light Curtain Replacement

For ReeR EOS2 Series 40 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height X Safety Light Curtain Replacement

For ReeR EOS2 Series 40 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height X Safety Light Curtain Replacement
For ReeR EOS2 Series 40 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height X Safety Light Curtain ReplacementFor ReeR EOS2 Series 40 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height X Safety Light Curtain ReplacementFor ReeR EOS2 Series 40 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height X Safety Light Curtain ReplacementFor ReeR EOS2 Series 40 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height X Safety Light Curtain ReplacementFor ReeR EOS2 Series 40 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height X Safety Light Curtain Replacement
CategoriesReeR Safety Light Curtains Replacement
BrandDADISICK
ModelEOS2 Series | EOS2 154 X, EOS2 254 X, EOS2 304 X, EOS2 454 X, EOS2 604 X, EOS2 754 X, EOS2 904 X, EOS2 1054 X, EOS2 1204 X, EOS2 1354 X, EOS2 1504 X, EOS2 1654 X, EOS2 1804 X, EOS2 1954 X, EOS2 2104 X, EOS2 2254 X
Series:EOS2 Series
Resolution:40 mm
Scanning range:12 m
Protective field height:160 - 2260 mm
2 Safety outputs (OSSD):2 PNP
Response time:4 - 19 ms
Connection type:M12
security level:PLc2
Update TimeDec 5,2024
Detail Information
For ReeR EOS2 Series 30 mm Resolution 12 m Sensing Distance 1060 mm to 2260 mm Protective Height X Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
EOS2 154 X
QT06-40-200 2BD
EOS2 254 X
QT08-40-280 2BD
EOS2 304 X
QT08-40-280 2BD
EOS2 454 X
QT12-40-440 2BD
EOS2 604 X
QT16-40-600 2BD
EOS2 754 X
QT20-40-760 2BD
EOS2 904 X
QT24-40-920 2BD
EOS2 1054 X
QT28-40-1080 2BD
EOS2 1204 X
QT32-40-1240 2BD
EOS2 1354 X
QT34-40-1320 2BD
EOS2 1504 X
QT38-40-1480 2BD
EOS2 1654 X
QT42-40-1640 2BD
EOS2 1804 X
QT46-40-1800 2BD
EOS2 1954 X
QT50-40-1960 2BD
EOS2 2104 X
QT54-40-2120 2BD
EOS2 2254 X
QT58-40-2280 2BD
Beam spacing
40 mm
40 mm
Protected altitude
160 mm, 260 mm, 310 mm, 460 mm, 610 mm, 760 mm, 910 mm,1060 mm, 1210 mm, 1360 mm, 1510 mm, 1660 mm, 1810 mm, 1960 mm, 2110 mm, 2260 mm
200 mm, 280 mm,440 mm, 600 mm, 760 mm, 920 mm,  1080 mm, 1240 mm, 1320 mm, 1480 mm, 1640 mm, 1800 mm, 1960 mm, 2120 mm, 2280 mm 
Scanning range
12 m
0.3 - 15 m
Response time
4 - 19 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65, IP67
IP65
Connector
M12
M16
Housing cross-section
28 mm x 30 mm
51 mm x 35 mm
Safety Certificate
CE, TÜV, UL, TS, RoHS, UKCA, PLc2
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand ReeR's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK QT Series Machine Light Curtains
Model:
QT06-40-200 2BD, QT08-40-280 2BD, QT12-40-440 2BD
QT16-40-600 2BD, QT20-40-760 2BD, QT24-40-920 2BD
QT28-40-1080 2BD, QT32-40-1240 2BD, QT34-40-1320 2BD
QT38-40-1480 2BD, QT42-40-1640 2BD, QT46-40-1800 2BD
QT50-40-1960 2BD, QT54-40-2120 2BD, QT58-40-2280 2BD


FAQ
1.What tests should I perform after installing a new light screen?
We suggest conducting functional testing and security verification to ensure that the new light curtain can function properly. The testing items include detection range, response time, and alarm function.

2. Is the new light curtain compatible with the existing system?

We provide 1:1 customized replacement of the original light curtain data connector, with compatibility including electrical interfaces, communication protocols, and mechanical installation. Please compare the specifications of existing light curtains with ours, or contact our technical support team to help you find a compatible replacement model.

3. What standards do your safety light curtains meet?
Our light curtain products have undergone strict testing and comply with relevant safety standards in multiple countries and regions, such as Chinese GB/T 19001-2016, ISO 9001:2015, International Electrotechnical Society IEC61496-1/2 standard safety level, EU CE certification, and South Germany TUV certification.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT series-data sheet
Safety-light-curtain QT series user manual
Review