Home / All / Pilz Replacement / Pilz Safety Light Curtains Replacement /

For Pilz PSENopt Series 30 mm Resolution 19 m Sensing Distance 150 mm to 1350 mm Protective Height Basic Type 2 Light Curtain with Hand Protection Replacement

For Pilz PSENopt Series 30 mm Resolution 19 m Sensing Distance 150 mm to 1350 mm Protective Height Basic Type 2 Light Curtain with Hand Protection Replacement

For Pilz PSENopt Series 30 mm Resolution 19 m Sensing Distance 150 mm to 1350 mm Protective Height Basic Type 2 Light Curtain with Hand Protection Replacement
For Pilz PSENopt Series 30 mm Resolution 19 m Sensing Distance 150 mm to 1350 mm Protective Height Basic Type 2 Light Curtain with Hand Protection ReplacementFor Pilz PSENopt Series 30 mm Resolution 19 m Sensing Distance 150 mm to 1350 mm Protective Height Basic Type 2 Light Curtain with Hand Protection ReplacementFor Pilz PSENopt Series 30 mm Resolution 19 m Sensing Distance 150 mm to 1350 mm Protective Height Basic Type 2 Light Curtain with Hand Protection ReplacementFor Pilz PSENopt Series 30 mm Resolution 19 m Sensing Distance 150 mm to 1350 mm Protective Height Basic Type 2 Light Curtain with Hand Protection ReplacementFor Pilz PSENopt Series 30 mm Resolution 19 m Sensing Distance 150 mm to 1350 mm Protective Height Basic Type 2 Light Curtain with Hand Protection Replacement
CategoriesPilz Safety Light Curtains Replacement
BrandDADISICK
ModelPSENopt Series | PSEN op2H-s-30-015/1, PSEN op2H-s-30-030/1, PSEN op2H-s-30-045/1, PSEN op2H-s-30-060/1, PSEN op2H-s-30-075/1, PSEN op2H-s-30-090/1, PSEN op2H-s-30-105/1, PSEN op2H-s-30-120/1, PSEN op2H-s-30-135/1
Series:PSENopt Series
Resolution:30 mm
Scanning range:0.2 - 19 m
Protective field height:150 - 1350 mm
2 Safety outputs (OSSD):2 PNP
Response time:9 - 20 ms
Connection type:M12
security level:PLc2
Update TimeDec 5,2024
Detail Information
For Pilz PSENopt Series 30 mm Resolution 19 m Sensing Distance 150 mm to 1350 mm Protective Height Basic Type 2 Light Curtain with Hand Protection Replacement Parameter
Brand
From network
DADISICK
Models
PSEN op2H-s-30-015/1
QT08-20-140 2BE
PSEN op2H-s-30-030/1
QT16-20-300 2BE
PSEN op2H-s-30-045/1
QT24-20-460 2BE
PSEN op2H-s-30-060/1
QT30-20-580 2BE
PSEN op2H-s-30-075/1
QT38-20-740 2BE
PSEN op2H-s-30-090/1
QT46-20-900 2BE
PSEN op2H-s-30-105/1
QT54-20-1060 2BE
PSEN op2H-s-30-120/1
QT60-20-1180 2BE
PSEN op2H-s-30-135/1
QT68-20-1340 2BE
Beam spacing
30 mm
20 mm
Protected altitude
150 mm, 300 mm, 450 mm, 600 mm, 750 mm, 900 mm, 1050 mm, 1200 mm, 1350 mm
140 mm, 300 mm,460 mm, 580 mm, 740 mm, 900 mm, 1060 mm, 1180 mm, 1340 mm
Scanning range
0.2 - 19 m
0.3 - 20 m
Response time
9 ms - 20 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65
IP65
Connector
M12
M16
Housing cross-section
36.9 mm x 32.3 mm
51 mm x 35 mm
Safety Certificate
CE, cULus, TÜV, EAC
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Pilz's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK QMT Series Machine Light Curtains
Model:
QT08-20-140 2BE, QT16-20-300 2BE, QT24-20-460 2BE
QT30-20-580 2BE, QT38-20-740 2BE, QT46-20-900 2BE
QT54-20-1060 2BE, QT60-20-1180 2BE, QT68-20-1340 2BE






FAQ
Q: what is the difference between a level 2 safety light curtain and lever 4 safety light curtain ?

A:
Level 2 safety light curtains have the following characteristics:

1. Low cost: Level 2 safety light curtains are generally affordable compared to higher level light curtains.

2. Performance: Level 2 light curtains typically utilize a single CPU processor for their operation.

3. Dual safety channel outputs: They provide two separate output channels for enhanced safety redundancy and reliability4. Self-diagnosis or external periodic testing: Level 2 light curtains can perform self-diagnosis or be externally tested at regular intervals to check for any faults or malfunctions.

5. Fault exclusion method for safety performance: These light curtains employ fault exclusion techniques to ensure that they maintain their safety performance even in the presence of potential faults or failures.

6. Application range: Level 2 safety light curtains are suitable for use in situations or machines where the risk of injury is moderate or low. They are commonly used in automated production equipment, material handling devices, and similar applications.

Level 4 safety light curtains have the following characteristics:
1. Higher cost: Level 4 safety light curtains are generally more expensive compared to lower level light curtains due to their advanced features and performance.
2. Performance: Level 4 light curtains typically utilize dual CPU processors for increased processing power and reliability.
3. Dual safety channel outputs: Similar to level 2 light curtains, they provide two separate output channels for enhanced safety redundancy and reliability.
4. More reliable control, less susceptible to interference: Level 4 light curtains are designed to be less affected by ambient light or other sources of interference, ensuring more reliable operation.
5. Self-diagnosis and advanced fault detection: They incorporate self-diagnosis capabilities for fault checking and may have additional features such as higher-level redundant fault cross-checking.
6. Application range: Level 4 safety light curtains are suitable for use in high-risk environments or machines where the potential for serious injury is greater. They provide effective protection for dangerous areas.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT series-data sheet
Safety-light-curtain QT series user manual
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions