Home / All / RIKEN OPTECH Replacement / RIKEN OPTECH Safety Light Curtains Replacement /

For RIKEN OPTECH RFG414 Series 10 mm Resolution 10 m Sensing Distance 880 mm to 1880 mm Protective Height Extended Light Curtain Replacement

For RIKEN OPTECH RFG414 Series 10 mm Resolution 10 m Sensing Distance 880 mm to 1880 mm Protective Height Extended Light Curtain Replacement

For RIKEN OPTECH RFG414 Series 10 mm Resolution 10 m Sensing Distance 880 mm to 1880 mm Protective Height Extended Light Curtain Replacement
For RIKEN OPTECH RFG414 Series 10 mm Resolution 10 m Sensing Distance 880 mm to 1880 mm Protective Height Extended Light Curtain ReplacementFor RIKEN OPTECH RFG414 Series 10 mm Resolution 10 m Sensing Distance 880 mm to 1880 mm Protective Height Extended Light Curtain ReplacementFor RIKEN OPTECH RFG414 Series 10 mm Resolution 10 m Sensing Distance 880 mm to 1880 mm Protective Height Extended Light Curtain ReplacementFor RIKEN OPTECH RFG414 Series 10 mm Resolution 10 m Sensing Distance 880 mm to 1880 mm Protective Height Extended Light Curtain ReplacementFor RIKEN OPTECH RFG414 Series 10 mm Resolution 10 m Sensing Distance 880 mm to 1880 mm Protective Height Extended Light Curtain Replacement
CategoriesRIKEN OPTECH Safety Light Curtains Replacement
BrandDADISICK
ModelRFG414 Series | RFG414-980FL3, RFG414-1180FL3, RFG414-1380FL3, RFG414-1580FL3, RFG414-1780FL3, RFG414-1980FL3
Series:RFG414 Series
Resolution:10 mm
Scanning range:0.3 - 10 m
Protective field height:880 - 1880 mm
2 Safety outputs (OSSD):2 PNP
Response time:10 - 21 ms
Connection type:M12
security level:PLe4
Update TimeDec 5,2024
Detail Information
For RIKEN OPTECH RFG414 Series 10 mm Resolution 10 m Sensing Distance 880 mm to 1880 mm Protective Height Extended Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
RFG414-980FL3
QMT88-10-970 BC
RFG414-1180FL3
QMT108-10-1070 2BC
RFG414-1380FL3
QMT128-10-1270 2BC
RFG414-1580FL3
QMT148-10-1470 2BC
RFG414-1780FL3
QMT168-10-1670 2BC
RFG414-1980FL3
QMT188-10-1870 2BC
Beam spacing
10 mm
10 mm
Protected altitude
880 mm, 1080 mm, 1280 mm, 1480 mm, 1680 mm, 1880 mm
970 mm, 1070 mm, 1270 mm, 1470 mm, 1670 mm, 1870 mm
Scanning range
0.3 - 10 m
0.3 - 10 m
Response time
10 ms - 21 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65
IP65
Connector
M12
M16
Housing cross-section
32 mm x 38 mm
51 mm x 35 mm
Safety Certificate
CE, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand RIKEN OPTECH's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK QMT Series Machine Light Curtains
Model:
QMT88-10-970 BC, QMT108-10-1070 2BC, QMT128-10-1270 2BC
QMT148-10-1470 2BC, QMT168-10-1670 2BC, QMT188-10-1870 2BC






FAQ
Q:How to determine if a safety light curtain is working properly?
A:
Safety light curtains are also known as safety light screens, safety light curtain sensors, infrared safety light curtains, photoelectric protectors, infrared photoelectric protectors, punch press photoelectric protection devices, etc.

How to determine if a safety light curtain is in working mode?

Many customers may have doubts when using a light curtain for the first time, wondering if it is installed correctly and if it is in normal working mode.

Because the purpose of a safety light curtain is to protect personal safety, it must be taken seriously. So how can we determine if a safety light curtain is in working mode?

When the safety light curtain is powered on, the emitter will flash three times and then remain on, indicating that it has entered the working mode. The receiver will have red and green lights flashing three times when powered on, indicating that it has also entered the working mode.
What are the conditions for the safety light curtain to be working properly?

When the emitter and receiver are in working condition, the emitter's red light remains on, and the receiver's green light is illuminated. When the light curtain is obstructed, there is no change in the emitter's indicator light, but the receiver's light changes from green to red, and the digital display shows the number of blocked light beams. When there is no obstruction, the receiver returns to its normal state with a constant green light.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension